In all child care facilities, all nonlocking type, 125 volt, 15 and 20 ampere receptacles shall be listed tamper resistant receptacles. Nfpa 70e, standard for electrical safety in the workplace. Significant changes for the 2011 national electrical code. Significant changes of the 2011 nec provides authoritative, succinct, and indepth coverage of the major changes contained in the 2011 national electrical code nec the book is designed to efficiently convey code change information and save time for the code user by highlighting only the most significant changes in the 2011 nec. Some statescities rewrite the nec or provide addendums to the nec. Tamperresistant shutters provide compliance with 2011 nec code replace a standard duplex receptacle back and side wire for easy installation ul listed and fcc approved description features the topgreener tu2152a chargertamperresistant receptacle offers two usb charging ports and duplex tamperresistant receptacles. Adopted in all 50 states, the nec is the benchmark for safe electrical design. Under the 2011 nec, tamper resistant outlets are not required in locations higher than 5.
Thoroughly revised and expanded with hundreds of pages of new material to reflect changes in the 2011 nec, mcgrawhills national electrical code 2011. It was issued by the standards council on july 26, 2007, with an effective date of august. Mike holt worked his way up through the electrical trade from apprentice electrician through electrical contractor, to become one of the most recognized experts in the world as it relates to electrical power installations. The nec is considered a voluntary standard and its adoption is up to individual states andor local municipalities. The new building code is based on the 2009 international building code. Buy nfpa 70, national electrical code nec softbound. A good faith effort is made to maintain the accuracy and completeness of this list.
He was a journeyman electrician, master electrician, and electrical contractor. Rating is available when the video has been rented. This page provides a pdf document of nec adoption by jurisdiction. The city of arvada will adopt the 2011 national electric code nec along with the state of colorado on july 1, 2011. If you are a member of the nfpa you can download the 1993, 1996, and 1999 nec in pdf format and access the 2002 nec on line. A small change was made in order to comply with the nec style manual, and new text. How to get a free copy of the 2011 national electric code. Top 25 changes to the 2011 national electrical code nec. It is intended to be used as a practical working tool to assist in making the nec as clear. Standard for good workmanship in electrical construction. When nonconductive structural reinforcing steel is used in a pool, a bonding grid of 8 awg copper conductors is required, but previous editions of the code didnt address how. Mike holts illustrated guide to understanding the nec.
The purpose for the national electrical code is to provide a safe installation, but article 110 is perhaps focused a little more on providing an installation that is safe. Esfi tamper resistant receptacles trr code requirements. An arcfault circuit interrupter is a device intended to deenergize the circuit when it detects the current waveform characteristics unique to an arcing fault. Foyers that are not part of a hallway in accordance with 210. Unfortunately, the nfpa intentionally makes this free online version difficult to find and use. Tamperresistant 2011 nec compliant shutter mechanism blocks access to contacts from most foreign objects for improved safety. Cooper wiring tr1107w electrical outlet, tamper resistant. Uptodate with the latest electrical innovations, advanced techniques, and proven practices. Di t i d t st d ddirector, industry standards 2011 nec facts 5,016 public proposals 2,p910 public comments 22 certified amending motions at the nfpa annual meeting 7 were successful on the floor 7 appeals to the standards council all were denied. The next logical step was shared spaces used by children, as a result, 2011 nec required tr receptacles in guest rooms and guest suites, child care facilities, and. Implementation of the national electrical code nema. View and download nec nc900c installation manual online. Comprehensive provisions address electrical installations in virtually all buildings including commercial, residential, and industrial occupancies.
The next logical step was shared spaces used by children, as a result, 2011 nec. Wire terminals are designed for easy installation from the back or side ul listed compatibility tu2154a dual usb charger with 15a duplex tamper resistant receptacle features. In 1974, mike realized there was a need for quality electrical training and opened mike holt. Adopted in all 50 states, the nec helps protect people and property from electrical hazards involving wiring and equipment. Good workmanship shall be apparent in the installation of all electrical materials and equipment see figure1. The promulgation of the nec was through the state policefire marshalls office and the maryland state fire prevention commission. However, they do make available a limiteduse online copy of the 2011 nec. Table of contents viii mike holts illustrated guide to changes to the nec 2011 article 410luminaires, lampholders, and lamps 203. Other locations in the nec provide additional requirements where gfci protection is required for receptacles and specific equipment, whether cord and plug connected or directly wired. Assume for a second that my jurisdiction has adopted 2011 nec code as legally binding without significant amendment. New building codes effective january 1, 2011 notable code changes, national electric code nec 210. Article 728, fire resistive cable systems rop 3170.
This stateoftheart device has the ability to charge up to two electronic devices simultaneously utilizing the usb ports, leaving the receptacle free for additional power needs. Revisions for the 2011 national electrical code part 1 pdh online. National electrical code and nec are registered trademarks of the national. National electrical code 2008 edition this edition of nfpa 70, national electrical code, was prepared by the national electrical code committee and acted on by nfpa at its june association technical meeting held june 37, 2007, in boston, ma. The book alerts you to matters that will be areas of discussion with inspectors. Nfpa, national fire protection association, national electrical code, nfpa 70, and nec. National fire protection association errata errata 70112 issued 1242012 pdf, 18 kb errata 70111 issued 482011 pdf, 48 kb. Receptacles located within the rooms, bathrooms, playrooms, activity rooms, and patient care areas of designated pediatric locations shall be listed tamper resistant or shall employ a listed tamperresistant cover. Tamper resistant receptacles ecn electrical forums.
All 15 and 20ampere, 125 and 250volt nonlockingtype receptacles in the areas s pecified in 406. Nec 2009 pdf nfpa, 1 batterymarch park, quincy, ma 021697471. The nec as referenced in the adoption of nfpa 1 as of january 1. Based on industry feedback, the new code names some exemptions. The leviton usb chargertamperresistant receptacle offers a groundbreaking 2. Oct 11, 2012 the national electric code nec is published by the national fire protection association nfpa.
The complete electrical estimating deluxe dvd package is a must have for both new and experienced electrical contractors estimators. Tamperresistant receptacles are required outdoors at dwelling units and in all areas. The nfpa recovers part of its code development costs by selling code books. A combination of automatic and manual controls for the lighting is acceptable so long as a. The locations requiring tamperresistant receptacles have been expanded, as. Thoroughly revised and expanded to reflect changes in the 2011 nec, mcgrawhills national electrical code 2011 handbook, 27th edition provides authoritative guidance and analysis to help you accurately interpret 2011 nec rules.
In all child care facilities, all nonlocking type, 125 volt, 15 and 20 ampere receptacles shall be. Listed tamperresistant receptacles must be provided where replacements are made. The 2011 national electrical code is the vital link between electrical equipment and safe installation and use by consumers. The national electrical code nec style manual is prepared under. Receptacles in dedicated space for appliances not easily relocated. The commissioner is authorized to exercise all powers necessary to enforce the electrical code and the electrical code technical standards, including but not limited to the power to. Gfci protection is now required on certain threephase receptacles. The cost difference between tr and nontr receptacles is negligible in regard to new construction or renovation. Nfpa 70, national electrical code nfpa 70b, recommended practice for electrical equipment maintenance. Mcgrawhills national electrical code 2011 handbook, 27th edition. Bill can check his shelf, or order one from delmar. With your code book and mikes textbook, watch and listen to the dvds. A building or structure, or portion thereof, for educational, supervisory, or personal careservices for more than four children 7 yrs. Maryland has adopted the 2014 national electrical code nec.
White book, category aalz, electrical equipment for use in ordinary locations. The purpose for the national electrical code is to provide a safe installation, but article 110 is perhaps focused a little more on providing an installation that is safe for the installer and maintenance electrician, so time spent in. National electrical code name of standards organization. Because of this issue the 2011 nec has added a new section called guess what foyers 210. Article 393, low voltage suspended ceiling power distribution systems rop 1810a. Nyc 2011 electrical code administrative provisions 273005 jurisdiction, powers and duties of the commissioner. The connection of the copper bonding grid discussed in 680. Summary of the changes 2017 national electrical code. Where cable is run at angles with joist in unfinished basements and crawl spaces it shall be permissible to secure cables not smaller than two 6 awg or three 8 awg conductors directly to the lower edges of the joists.